HVAC, Plumber & Electrician in Newburgh, IN | A+ Derr
24/7 Customer Support
  • We're here whenever you need us at (812) 200-0727. Our 24/7 customer support team can answer your questions, schedule your service, and take a message for our team if you need a callback during normal business hours.
  • For true HVAC emergencies, an on-call technician may be available after hours. Plumbing and electrical service are available during normal service hours.
Call Today (812) 200-0727 Schedule Online
FREE ESTIMATE Schedule Today! Request Service

Heating, Cooling, Plumbing & Electrical Services in Newburgh, IN

 

Newburgh Service Overview

Based in Newburgh (Main Local Hub): Newburgh serves as the central operations hub for A+ Derr, housing our main local office and the largest home service fleet in the Tri-State area.

Four Multi-Trade Services: We deliver comprehensive heating, cooling, plumbing, and electrical solutions for homes across ZIP code 47630.

Decades of Local Experience: Our technicians handle everything from historic Riverfront and Old Lock and Dam properties with multi-generational mechanicals to expansive newer builds near Castle High School.

 

Newburgh’s housing changes quickly as you travel away from the Ohio River. Historic properties near the Riverfront and Old Lock and Dam may have mechanical systems updated in stages over several decades. Homes in newer parts of Newburgh often have larger layouts, modern equipment, and growing electrical demands. A+ Derr provides heating, cooling, plumbing, and electrical services throughout Newburgh from our main local office.

“Pleasure doing business with them. New HVAC system and water heater. Everyone I dealt with was extremely friendly, helpful and knowledgeable. Had an issue with water pressure in kitchen and bathroom sinks and they got it corrected for me. Definitely recommend.”

Lori M.

Need an experienced HVAC contractor, plumber, or electrician in Newburgh, IN? Call (812) 200-0727 or contact our local office online today!

A+ Derr Is Based in Newburgh

Newburgh is the center of A+ Derr’s Tri-State operation. Our main office is located here, and our technicians leave from this local hub to serve customers throughout the area. With one of the largest home service fleets in the region, A+ Derr vehicles are a familiar sight around Newburgh each day.

Our local connection extends beyond the homes we service. A+ Derr sponsors sports and clubs at various schools across the area. We also participate in the Newburgh Holiday Light Parade each year. These relationships keep our company connected to the schools, families, and traditions that shape the community.

Solving HVAC, Plumbing, Electrical Issues in Newburgh Homes

Problem: Persistent river valley humidity during hot summer months makes indoor air feel warm and damp, even when AC units run continuously.

Solution: A+ Derr installs whole-home dehumidifiers, air purifiers, ductless mini-splits, and high-efficiency replacement air conditioners or heat pumps to actively balance humidity and cooling.

Problem: Historic homes near the Riverfront feature narrow ductwork, converted upper floors, and older electrical panels that cannot support new appliances or HVAC upgrades.

Solution: Our team performs complete electrical panel upgrades, meter upgrades, custom duct balancing, and mini-split additions to modernize comfort without disrupting historic structures.

Problem: Sudden winter freezes expose worn furnace parts, thermostat glitches, and airflow bottlenecks in drafty or open-concept floor plans.

Solution: We provide emergency furnace repairs, heat pump services, boiler replacements, and preventive winter tune-ups to ensure consistent heat.

Problem: Heavy rainstorms tax basements, crawl spaces, and low-lying foundations, increasing the risk of drainage failures and water damage.

Solution: Our master plumbers service and replace sump pumps, repair sewer lines, clear drain blockages, and perform complete pipe repairs or repiping.

Rapid AC Repair & Whole-Home Dehumidification for Newburgh Summers

Newburgh summers bring high heat and persistent river valley humidity. Your air conditioner must remove moisture while cooling the house, which places added stress on older equipment. Poor airflow, limited insulation, or improper system sizing can leave rooms feeling warm and damp even when the AC continues to run.

Our local cooling services include:

Homes close to the Riverfront may have narrow duct routes, converted upper floors, or additions that receive limited airflow. Newer Newburgh properties may experience temperature differences caused by tall ceilings, open floor plans, or long duct runs. Our technicians inspect the equipment and supporting comfort system before recommending repairs or replacement.

“AC went out. I called and literally 30 mins later they was here! I was blown away. It’s been raining pretty much all day. The guy never quit! I told him it’s ok come out of the rain. But he wanted to get this done for me. Can’t thank you guys enough.”

Rob R.

Is Ohio River Valley humidity making your home feel warm and sticky? Call our local Newburgh team at (812) 200-0727 or schedule online for high-efficiency AC repair and dehumidification solutions!

Newburgh Plumbing Services: Sump Pumps, Water Heaters & Repiping

Plumbing needs often reflect a property’s construction history. Some older Newburgh homes contain multiple generations of pipes, fixtures, and drain connections hidden behind remodeled walls. Newer homes can face different problems, including water pressure changes, water heater failures, fixture leaks, and heavy hot water demand.

A+ Derr provides:

  • Leak and pipe repair
  • Kitchen and bathroom plumbing
  • Plumbing maintenance
  • Standard water heater service
  • Tankless water heater installation
  • Sump pump replacement
  • Sewer and drain service
  • Garbage disposal repair
  • Toilet installation and repair
  • Piping and repiping
  • Water filtration systems

Strong storms can test sump pumps and drainage systems throughout Newburgh, especially in homes with basements, crawl spaces, or low areas around the foundation. Our plumbers locate the cause of the issue and explain whether a repair, equipment replacement, or piping improvement provides the right solution.

Furnace Repair & Dependable Winter Heating in 47630

Newburgh can move from moderate weather to freezing temperatures in a short period. That sudden demand often exposes worn furnace components, weak airflow, thermostat problems, and heat pumps that have not received seasonal maintenance.

Our heating services include:

A home near historic downtown may lose heat through insulation gaps or rooms outside the original duct layout. Larger properties near Castle High School and newer development may struggle with uneven temperatures between floors or distant rooms. A+ Derr tests the heating equipment, thermostat, airflow, and duct system to identify the source of the problem.

Don’t let a sudden Southern Indiana freeze leave your home in the cold. Call A+ Derr in Newburgh at (812) 200-0727 for fast, reliable furnace repair and heating system tune-ups!

Electrical Panel Upgrades, EV Chargers & Generators in Newburgh

Electrical demand has changed across Newburgh. Older properties may have panels that predate modern kitchens, central HVAC equipment, home offices, and connected electronics. Newer homes may need added capacity for electric vehicles, outdoor living areas, backup generators, and finished lower levels.

Our electrical services include:

A renovated Riverfront property may need electrical improvements before receiving new HVAC equipment or appliances. A newer Newburgh home may require an EV charger, generator connection, landscape lighting, or circuits for a basement project. Our electricians evaluate the existing capacity and planned load before completing the installation.

Upgrading appliances or noticing flickering lights in your 47630 home? Call our local Newburgh electricians at (812) 200-0727 or schedule online for panel upgrades, safety inspections, and rewiring!

Why Newburgh Homeowners Choose A+ Derr

Our main office is located here, and our technicians serve local homes every day. That regular presence gives our team firsthand experience with historic riverfront properties, established neighborhoods, and the newer homes appearing around the outskirts of town.

Customers choose A+ Derr for:

  • A main office in Newburgh
  • One of the Tri-State’s largest fleets
  • Four home service trades
  • Experience with varied local homes
  • Emergency HVAC availability
  • Coordinated project support
  • Local community involvement

Our sponsorship of local sports and clubs reinforce that connection. We work in Newburgh, support Newburgh organizations, and remain part of the community after each service call is complete.

Schedule HVAC, Plumbing & Electrical Service in Newburgh, IN Today

No matter if your home is a historic property along the Newburgh Riverfront or a newer build elsewhere in 47630, A+ Derr is ready to keep your essential systems running smoothly. Our local team handles everything from repairs and routine maintenance to full replacements and new installations for heating, cooling, plumbing, and electrical systems.

Proudly headquartered in Newburgh and serving all of 47630 and Warrick County. Call (812) 200-0727 to book your service with A+ Derr!

FAQs for Newburgh Homeowners

Newburgh is our main local hub and home to our central office. Housing one of the largest fleets in the Tri-State area right in 47630 allows us to offer rapid dispatch and emergency service for nearby homes.

Historic properties often suffer from narrow ductwork or converted upper levels. Installing supplemental ductless mini-splits or whole-home dehumidifiers regulates temperature and moisture without invasive construction.

Older panels in established neighborhoods may predate high-demand HVAC units, kitchen remodels, or EV chargers. A panel or meter upgrade ensures your system safely handles increased power demands.

Heavy river valley rainfall can quickly strain foundation drainage. Routine sump pump testing and timely replacement protect basements and crawl spaces from costly storm-related flooding.

Turn off the system at the thermostat or breaker to prevent damage, check for dirty filters or tripped switches, and call us for immediate emergency service.

Page Updated on August 11, 2026

Recent Jobs and Reviews in Newburgh, IN

Newburgh, IN at a glance

A+ Derr Heating & Cooling has completed 20 jobs in Newburgh, IN in June 2026.

The most recent job was on June 29, 2026.

A+ Derr Heating & Cooling has completed 1,761 jobs in Newburgh, IN in the last 12 months.

Job Locations and Reviews

Completed installation of State ProLine water heater in basement utility area, including all required water supply connections with copper piping and brass fittings. Installed gas line with appropriate shutoff valve and safety controls. Mounted and connected water softener system to incoming water supply line to provide whole-house water treatment. Installed customer-supplied kitchen sink with proper drainage connections and supply lines. All installations performed to code specifications with secure mounting, proper venting, and leak-free connections. Verified system operation and water flow throughout all installed fixtures and appliances.
Completed installation of State ProLine water heater in basement utility area, including all required water supply connections with copper piping and brass fittings. Installed gas line with appropriate shutoff valve and safety controls. Mounted and connected water softener system to incoming water supply line to provide whole-house water treatment. Installed customer-supplied kitchen sink with proper drainage connections and supply lines. All installations performed to code specifications with secure mounting, proper venting, and leak-free connections. Verified system operation and water flow throughout all installed fixtures and appliances.
Isaac G.
Isaac G. Checked in
Completed installation of State ProLine water heater in basement utility area, including all required water supply connections with copper piping and brass fittings. Installed gas line with appropriate shutoff valve and safety controls. Mounted and connected water softener system to incoming water supply line to provide whole-house water treatment. Installed customer-supplied kitchen sink with proper drainage connections and supply lines. All installations performed to code specifications with secure mounting, proper venting, and leak-free connections. Verified system operation and water flow throughout all installed fixtures and appliances.
Newburgh, IN 47630
Newburgh, IN - Responded to no-cooling callback on recent system installation. Upon arrival, found indoor temperature at 74°F with thermostat set to 68°F. Inspected crawl space ductwork installation and identified improperly secured flexible duct runs affecting airflow efficiency. Corrected duct connections, verified proper sealing at all joints, and ensured adequate support throughout the system. Tested unit operation, confirmed proper airflow at all registers, and verified system achieved target temperature with normal runtime and temperature differential.
Tyler C.
Tyler C. Checked in
Responded to no-cooling callback on recent system installation. Upon arrival, found indoor temperature at 74°F with thermostat set to 68°F. Inspected crawl space ductwork installation and identified improperly secured flexible duct runs affecting airflow efficiency. Corrected duct connections, verified proper sealing at all joints, and ensured adequate support throughout the system. Tested unit operation, confirmed proper airflow at all registers, and verified system achieved target temperature with normal runtime and temperature differential.
Newburgh, IN 47630
Newburgh, IN - Responded to no cooling call on 5-year-old residential system with indoor temperature at 82°F and thermostat set to 73°F. Upon inspection of outdoor condensing unit, diagnosed failed dual-run capacitor (Capcom model D1374G5P03) preventing compressor operation. Replaced defective capacitor, verified proper electrical connections, tested system startup and operation, and confirmed unit returned to normal cooling function with proper amperage draw on compressor and condenser fan motor.
Kevin H.
Kevin H. Checked in
Responded to no cooling call on 5-year-old residential system with indoor temperature at 82°F and thermostat set to 73°F. Upon inspection of outdoor condensing unit, diagnosed failed dual-run capacitor (Capcom model D1374G5P03) preventing compressor operation. Replaced defective capacitor, verified proper electrical connections, tested system startup and operation, and confirmed unit returned to normal cooling function with proper amperage draw on compressor and condenser fan motor.
Newburgh, IN 47630
Newburgh, IN - Responded to no-cool call on 9-year-old system displaying error code E73 on thermostat with no airflow from vents. Found tripped breakers had been reset by occupant prior to arrival without system recovery. Performed diagnostic evaluation of outdoor unit, inspecting electrical connections, refrigerant lines, and valve assembly. Identified failed contactor preventing compressor engagement. Replaced defective contactor, verified proper electrical continuity, and tested system startup sequence. Confirmed adequate airflow, proper refrigerant pressures, and normal operating temperatures across evaporator and condenser coils. System restored to full cooling operation with all components functioning within manufacturer specifications.
Kevin H.
Kevin H. Checked in
Responded to no-cool call on 9-year-old system displaying error code E73 on thermostat with no airflow from vents. Found tripped breakers had been reset by occupant prior to arrival without system recovery. Performed diagnostic evaluation of outdoor unit, inspecting electrical connections, refrigerant lines, and valve assembly. Identified failed contactor preventing compressor engagement. Replaced defective contactor, verified proper electrical continuity, and tested system startup sequence. Confirmed adequate airflow, proper refrigerant pressures, and normal operating temperatures across evaporator and condenser coils. System restored to full cooling operation with all components functioning within manufacturer specifications.
Newburgh, IN 47630
Newburgh, IN - Responded to service call for air conditioning system struggling to maintain temperature during hot weather. Upon arrival, performed comprehensive system evaluation including inspection of outdoor condensing unit and indoor air handler components. Unit was operational but running extended cycles due to reduced efficiency. Accessed attic-mounted air handler and ductwork for thorough inspection. Checked refrigerant levels, electrical connections, and airflow parameters. Identified reduced system performance likely attributed to maintenance needs and seasonal strain from extreme temperatures. System components showed no signs of mechanical failure, unusual noises, refrigerant leaks, or physical damage. Documented findings with photographic evidence of attic installation and equipment condition for service records.
Cameron N.
Cameron N. Checked in
Responded to service call for air conditioning system struggling to maintain temperature during hot weather. Upon arrival, performed comprehensive system evaluation including inspection of outdoor condensing unit and indoor air handler components. Unit was operational but running extended cycles due to reduced efficiency. Accessed attic-mounted air handler and ductwork for thorough inspection. Checked refrigerant levels, electrical connections, and airflow parameters. Identified reduced system performance likely attributed to maintenance needs and seasonal strain from extreme temperatures. System components showed no signs of mechanical failure, unusual noises, refrigerant leaks, or physical damage. Documented findings with photographic evidence of attic installation and equipment condition for service records.
Newburgh, IN 47630
Responded to no cooling call on 16-year-old system with complete unit failure. Upon inspection, found control board had failed, preventing system from powering on. Replaced defective circuit board and capacitor, restored all electrical connections, and tested system operation. Unit now cooling properly with all components functioning within normal parameters.
Responded to no cooling call on 16-year-old system with complete unit failure. Upon inspection, found control board had failed, preventing system from powering on. Replaced defective circuit board and capacitor, restored all electrical connections, and tested system operation. Unit now cooling properly with all components functioning within normal parameters.
Cameron N.
Cameron N. Checked in
Responded to no cooling call on 16-year-old system with complete unit failure. Upon inspection, found control board had failed, preventing system from powering on. Replaced defective circuit board and capacitor, restored all electrical connections, and tested system operation. Unit now cooling properly with all components functioning within normal parameters.
Newburgh, IN 47630
Responded to no cooling complaint on 6-year-old residential air conditioning system with thermostat set to 70°F but home temperature at 75°F. Upon inspection, tested the outdoor unit's capacitor using multimeter and found failed capacitor with 0.000 reading. Replaced defective capacitor, verified proper electrical connections, and restored system to normal cooling operation.
Responded to no cooling complaint on 6-year-old residential air conditioning system with thermostat set to 70°F but home temperature at 75°F. Upon inspection, tested the outdoor unit's capacitor using multimeter and found failed capacitor with 0.000 reading. Replaced defective capacitor, verified proper electrical connections, and restored system to normal cooling operation.
Christian C.
Christian C. Checked in
Responded to no cooling complaint on 6-year-old residential air conditioning system with thermostat set to 70°F but home temperature at 75°F. Upon inspection, tested the outdoor unit's capacitor using multimeter and found failed capacitor with 0.000 reading. Replaced defective capacitor, verified proper electrical connections, and restored system to normal cooling operation.
Newburgh, IN 47630
Conducted comprehensive replacement estimate for non-operational residential air conditioning system. Evaluated existing outdoor condensing unit mounted on brick platform against house exterior, assessed electrical conduit and disconnect box configuration, and inspected indoor thermostat wiring connections to determine compatibility requirements for new equipment installation.
Conducted comprehensive replacement estimate for non-operational residential air conditioning system. Evaluated existing outdoor condensing unit mounted on brick platform against house exterior, assessed electrical conduit and disconnect box configuration, and inspected indoor thermostat wiring connections to determine compatibility requirements for new equipment installation.
James W.
James W. Checked in
Conducted comprehensive replacement estimate for non-operational residential air conditioning system. Evaluated existing outdoor condensing unit mounted on brick platform against house exterior, assessed electrical conduit and disconnect box configuration, and inspected indoor thermostat wiring connections to determine compatibility requirements for new equipment installation.
Newburgh, IN 47630
Responded to A+ callback for newly installed system experiencing short cycling and water leakage from furnace area. Upon arrival, found air handler with significant moisture damage and water staining on cabinet exterior and surrounding flooring. Inspected condensate drain system and discovered improper drainage causing water to overflow from drain pan. Cleared condensate line obstruction, verified proper trap installation, and confirmed drain line was flowing freely. Tested system operation through complete cooling cycle to ensure short cycling issue was resolved and no further water leakage occurred. System restored to proper working condition with adequate drainage and normal cycling performance.
Responded to A+ callback for newly installed system experiencing short cycling and water leakage from furnace area. Upon arrival, found air handler with significant moisture damage and water staining on cabinet exterior and surrounding flooring. Inspected condensate drain system and discovered improper drainage causing water to overflow from drain pan. Cleared condensate line obstruction, verified proper trap installation, and confirmed drain line was flowing freely. Tested system operation through complete cooling cycle to ensure short cycling issue was resolved and no further water leakage occurred. System restored to proper working condition with adequate drainage and normal cycling performance.
Adam M.
Adam M. Checked in
Responded to A+ callback for newly installed system experiencing short cycling and water leakage from furnace area. Upon arrival, found air handler with significant moisture damage and water staining on cabinet exterior and surrounding flooring. Inspected condensate drain system and discovered improper drainage causing water to overflow from drain pan. Cleared condensate line obstruction, verified proper trap installation, and confirmed drain line was flowing freely. Tested system operation through complete cooling cycle to ensure short cycling issue was resolved and no further water leakage occurred. System restored to proper working condition with adequate drainage and normal cycling performance.
Newburgh, IN 47630
Responded to no cooling call on 10-year-old system with suspected lightning strike damage to outdoor unit. Upon arrival, confirmed tripped breaker and complete loss of cooling function. Diagnostic inspection revealed damaged control board in outdoor unit with visible component failure on PCB, including compromised relays and capacitors. Replaced defective control board and verified proper wiring connections at both outdoor unit and thermostat. Restored power, tested system operation through complete cooling cycle, and confirmed proper function of all components with normal amperage draw and temperature differential.
Responded to no cooling call on 10-year-old system with suspected lightning strike damage to outdoor unit. Upon arrival, confirmed tripped breaker and complete loss of cooling function. Diagnostic inspection revealed damaged control board in outdoor unit with visible component failure on PCB, including compromised relays and capacitors. Replaced defective control board and verified proper wiring connections at both outdoor unit and thermostat. Restored power, tested system operation through complete cooling cycle, and confirmed proper function of all components with normal amperage draw and temperature differential.
Kevin H.
Kevin H. Checked in
Responded to no cooling call on 10-year-old system with suspected lightning strike damage to outdoor unit. Upon arrival, confirmed tripped breaker and complete loss of cooling function. Diagnostic inspection revealed damaged control board in outdoor unit with visible component failure on PCB, including compromised relays and capacitors. Replaced defective control board and verified proper wiring connections at both outdoor unit and thermostat. Restored power, tested system operation through complete cooling cycle, and confirmed proper function of all components with normal amperage draw and temperature differential.
Newburgh, IN 47630
Responded to service call for 10-year-old HVAC system continuously running with thermostat set to 75°F while indoor temperature had dropped to 68°F. Upon inspection, diagnosed faulty thermostat failing to signal compressor to cycle off when setpoint was reached. Removed malfunctioning thermostat from wall, verified wiring connections at terminal block, and installed replacement thermostat. Tested system operation through multiple cooling cycles to confirm proper communication between thermostat and HVAC unit, verifying unit now cycles on and off correctly at desired temperature setpoint.
Responded to service call for 10-year-old HVAC system continuously running with thermostat set to 75°F while indoor temperature had dropped to 68°F. Upon inspection, diagnosed faulty thermostat failing to signal compressor to cycle off when setpoint was reached. Removed malfunctioning thermostat from wall, verified wiring connections at terminal block, and installed replacement thermostat. Tested system operation through multiple cooling cycles to confirm proper communication between thermostat and HVAC unit, verifying unit now cycles on and off correctly at desired temperature setpoint.
Christian C.
Christian C. Checked in
Responded to service call for 10-year-old HVAC system continuously running with thermostat set to 75°F while indoor temperature had dropped to 68°F. Upon inspection, diagnosed faulty thermostat failing to signal compressor to cycle off when setpoint was reached. Removed malfunctioning thermostat from wall, verified wiring connections at terminal block, and installed replacement thermostat. Tested system operation through multiple cooling cycles to confirm proper communication between thermostat and HVAC unit, verifying unit now cycles on and off correctly at desired temperature setpoint.
Newburgh, IN 47630
Completed annual AC tune-up maintenance on residential air conditioning system. Performed electrical diagnostics on outdoor condenser unit, recording voltage readings of 40.77 using digital multimeter, and measured supply air temperature at interior register confirming proper cooling output at 68.8°F. System operating within normal parameters with no deficiencies noted.
Completed annual AC tune-up maintenance on residential air conditioning system. Performed electrical diagnostics on outdoor condenser unit, recording voltage readings of 40.77 using digital multimeter, and measured supply air temperature at interior register confirming proper cooling output at 68.8°F. System operating within normal parameters with no deficiencies noted.
Michael H.
Michael H. Checked in
Completed annual AC tune-up maintenance on residential air conditioning system. Performed electrical diagnostics on outdoor condenser unit, recording voltage readings of 40.77 using digital multimeter, and measured supply air temperature at interior register confirming proper cooling output at 68.8°F. System operating within normal parameters with no deficiencies noted.
Newburgh, IN 47630
Completed dismissed visit maintenance on a 6-year-old single HVAC system. Inspected furnace unit in utility room, verified operational status of all mechanical components, and documented equipment condition with warning labels intact. Accessed attic space to examine ductwork installation, confirmed proper insulation wrapping on flexible ducts with pink and yellow fiberglass sleeves secured with straps, and assessed loose-fill attic insulation coverage. Replaced 16x25x5 air filter as part of routine maintenance protocol. All systems found in normal operating condition with no immediate service needs identified during this first scheduled visit since previous maintenance in June 2024.
Completed dismissed visit maintenance on a 6-year-old single HVAC system. Inspected furnace unit in utility room, verified operational status of all mechanical components, and documented equipment condition with warning labels intact. Accessed attic space to examine ductwork installation, confirmed proper insulation wrapping on flexible ducts with pink and yellow fiberglass sleeves secured with straps, and assessed loose-fill attic insulation coverage. Replaced 16x25x5 air filter as part of routine maintenance protocol. All systems found in normal operating condition with no immediate service needs identified during this first scheduled visit since previous maintenance in June 2024.
Kevin H.
Kevin H. Checked in
Completed dismissed visit maintenance on a 6-year-old single HVAC system. Inspected furnace unit in utility room, verified operational status of all mechanical components, and documented equipment condition with warning labels intact. Accessed attic space to examine ductwork installation, confirmed proper insulation wrapping on flexible ducts with pink and yellow fiberglass sleeves secured with straps, and assessed loose-fill attic insulation coverage. Replaced 16x25x5 air filter as part of routine maintenance protocol. All systems found in normal operating condition with no immediate service needs identified during this first scheduled visit since previous maintenance in June 2024.
Newburgh, IN 47630
Responded to service call for thermostat connectivity issues following homeowner's attempted replacement of Lennox iComfort thermostat with aftermarket unit. Upon arrival, found original Lennox iComfort thermostat reinstalled but displaying only startup screen and unable to establish communication with HVAC system. Diagnosed communication failure between thermostat and furnace control board, likely caused by improper wiring sequence during replacement attempt. Verified system airflow present and cooling operation functional at equipment level. Reconnected and reconfigured iComfort thermostat wiring to manufacturer specifications, restored proper communication protocol between thermostat and system controls, and successfully re-established full thermostat functionality with temperature display and system status information.
Responded to service call for thermostat connectivity issues following homeowner's attempted replacement of Lennox iComfort thermostat with aftermarket unit. Upon arrival, found original Lennox iComfort thermostat reinstalled but displaying only startup screen and unable to establish communication with HVAC system. Diagnosed communication failure between thermostat and furnace control board, likely caused by improper wiring sequence during replacement attempt. Verified system airflow present and cooling operation functional at equipment level. Reconnected and reconfigured iComfort thermostat wiring to manufacturer specifications, restored proper communication protocol between thermostat and system controls, and successfully re-established full thermostat functionality with temperature display and system status information.
Craig U.
Craig U. Checked in
Responded to service call for thermostat connectivity issues following homeowner's attempted replacement of Lennox iComfort thermostat with aftermarket unit. Upon arrival, found original Lennox iComfort thermostat reinstalled but displaying only startup screen and unable to establish communication with HVAC system. Diagnosed communication failure between thermostat and furnace control board, likely caused by improper wiring sequence during replacement attempt. Verified system airflow present and cooling operation functional at equipment level. Reconnected and reconfigured iComfort thermostat wiring to manufacturer specifications, restored proper communication protocol between thermostat and system controls, and successfully re-established full thermostat functionality with temperature display and system status information.
Newburgh, IN 47630
Completed comprehensive HVAC system replacement estimate for non-operational residential heating and cooling system requiring immediate replacement. Evaluated existing equipment condition, assessed installation site including indoor thermostat location and outdoor unit placement area adjacent to brick exterior wall, documented current system configuration, and provided detailed replacement options for complete system changeover.
Completed comprehensive HVAC system replacement estimate for non-operational residential heating and cooling system requiring immediate replacement. Evaluated existing equipment condition, assessed installation site including indoor thermostat location and outdoor unit placement area adjacent to brick exterior wall, documented current system configuration, and provided detailed replacement options for complete system changeover.
Nick B.
Nick B. Checked in
Completed comprehensive HVAC system replacement estimate for non-operational residential heating and cooling system requiring immediate replacement. Evaluated existing equipment condition, assessed installation site including indoor thermostat location and outdoor unit placement area adjacent to brick exterior wall, documented current system configuration, and provided detailed replacement options for complete system changeover.
Newburgh, IN 47630
Completed Platinum Level maintenance on 1-year-old residential HVAC system during first annual service visit. Performed comprehensive system inspection, tested temperature differentials across supply and return air using calibrated digital thermometer, verified proper airflow through ductwork, and inspected gas furnace and associated components. Replaced 20x25x5 air filter, checked all electrical connections, examined condensate drainage system, and confirmed safe operation of heating equipment with proper combustion and venting through PVC piping.
Completed Platinum Level maintenance on 1-year-old residential HVAC system during first annual service visit. Performed comprehensive system inspection, tested temperature differentials across supply and return air using calibrated digital thermometer, verified proper airflow through ductwork, and inspected gas furnace and associated components. Replaced 20x25x5 air filter, checked all electrical connections, examined condensate drainage system, and confirmed safe operation of heating equipment with proper combustion and venting through PVC piping.
Michael H.
Michael H. Checked in
Completed Platinum Level maintenance on 1-year-old residential HVAC system during first annual service visit. Performed comprehensive system inspection, tested temperature differentials across supply and return air using calibrated digital thermometer, verified proper airflow through ductwork, and inspected gas furnace and associated components. Replaced 20x25x5 air filter, checked all electrical connections, examined condensate drainage system, and confirmed safe operation of heating equipment with proper combustion and venting through PVC piping.
Newburgh, IN 47630
Newburgh, IN - Responded to no cooling call on 15-year-old Bryant single-unit dual-zone system unable to maintain 70-degree setpoint in either zone. Performed diagnostic evaluation of furnace and air handler assembly, inspected airflow delivery through vents, confirmed no evaporator coil icing present, and assessed zoning system performance and damper operation to identify inadequate cooling capacity issue affecting both zones.
Cameron N.
Cameron N. Checked in
Responded to no cooling call on 15-year-old Bryant single-unit dual-zone system unable to maintain 70-degree setpoint in either zone. Performed diagnostic evaluation of furnace and air handler assembly, inspected airflow delivery through vents, confirmed no evaporator coil icing present, and assessed zoning system performance and damper operation to identify inadequate cooling capacity issue affecting both zones.
Newburgh, IN 47630
Completed scheduled air conditioning tune-up and preventive maintenance inspection. Performed comprehensive system evaluation including refrigerant line inspection, electrical measurements, and condenser coil assessment. All components operating within normal parameters; temperature readings confirmed proper system performance at 58.04°F, gas valve and connections inspected and found secure, and photographic documentation captured for maintenance records.
Completed scheduled air conditioning tune-up and preventive maintenance inspection. Performed comprehensive system evaluation including refrigerant line inspection, electrical measurements, and condenser coil assessment. All components operating within normal parameters; temperature readings confirmed proper system performance at 58.04°F, gas valve and connections inspected and found secure, and photographic documentation captured for maintenance records.
Michael H.
Michael H. Checked in
Completed scheduled air conditioning tune-up and preventive maintenance inspection. Performed comprehensive system evaluation including refrigerant line inspection, electrical measurements, and condenser coil assessment. All components operating within normal parameters; temperature readings confirmed proper system performance at 58.04°F, gas valve and connections inspected and found secure, and photographic documentation captured for maintenance records.
Newburgh, IN 47630
Newburgh, IN - Responded to no cooling complaint and performed system diagnostics. Inspected indoor unit components, verified electrical connections and control board operation, and documented system condition with photos. All wiring connections found secure with proper wire terminations throughout the unit compartment.
Danny M.
Danny M. Checked in
Responded to no cooling complaint and performed system diagnostics. Inspected indoor unit components, verified electrical connections and control board operation, and documented system condition with photos. All wiring connections found secure with proper wire terminations throughout the unit compartment.
Newburgh, IN 47630
Completed annual Gold Level preventive maintenance on 20-year-old residential HVAC system including furnace and outdoor Payton condenser unit. Performed comprehensive inspection of all components, tested system operation and electrical connections, verified proper refrigerant levels, cleaned condenser coils, and replaced air filter. All equipment found operating within normal parameters with no immediate service needs identified at this time.
Completed annual Gold Level preventive maintenance on 20-year-old residential HVAC system including furnace and outdoor Payton condenser unit. Performed comprehensive inspection of all components, tested system operation and electrical connections, verified proper refrigerant levels, cleaned condenser coils, and replaced air filter. All equipment found operating within normal parameters with no immediate service needs identified at this time.
Francis I.
Francis I. Checked in
Completed annual Gold Level preventive maintenance on 20-year-old residential HVAC system including furnace and outdoor Payton condenser unit. Performed comprehensive inspection of all components, tested system operation and electrical connections, verified proper refrigerant levels, cleaned condenser coils, and replaced air filter. All equipment found operating within normal parameters with no immediate service needs identified at this time.
Newburgh, IN 47630
Start Saving Today With

Membership Perks

Start Saving Today With

Membership Perks

What To Expect

Discover The A+ Derr Difference

24/7 Heating & Cooling Repairs​

Heating and cooling emergencies can happen on nights, weekends, and holidays, so you can trust us to be there no matter when you need us.

Licensed & Experienced Technicians​

Our experts have the expertise and training to deliver the highest quality services every time.

100% Satisfaction Guarantee​

Our team is dedicated to ensuring your 100% satisfaction with every HVAC service we perform.

Servicing All Major Makes & Models Of Equipment

We are a Lennox Premier Dealer and also service on all makes and models of equipment, including Goodman, Amana, Carrier, Trane, Rheem & more!

Locally Owned & Operated​

Since we’re based in Kentuckiana, we know the needs of Evansville, Louisville, and surrounding communities.

50+ Years in Business​

For over 50 years, A+ Derr has provided high-quality service, products, and results for Kentuckiana's residents.

24/7 Heating & Cooling Repairs​

Heating and cooling emergencies can happen on nights, weekends, and holidays, so you can trust us to be there no matter when you need us.

Licensed & Experienced Technicians​

Our experts have the expertise and training to deliver the highest quality services every time.

100% Satisfaction Guarantee​

Our team is dedicated to ensuring your 100% satisfaction with every HVAC service we perform.

Servicing All Major Makes & Models Of Equipment

We are a Lennox Premier Dealer and also service on all makes and models of equipment, including Goodman, Amana, Carrier, Trane, Rheem & more!

Locally Owned & Operated​

Since we’re based in Kentuckiana, we know the needs of Evansville, Louisville, and surrounding communities.

50+ Years in Business​

For over 50 years, A+ Derr has provided high-quality service, products, and results for Kentuckiana's residents.

Review Image
Our Reviews

See What Your Neighbors Are Saying

I would recommend A+ Derr and their staff any day! Best service I have ever had! Go to them for your Heating and Cooling needs. You will not be disappointed.

Barbara C.

Barbara C.

Very good service. Knowledgeable HVAC experts always keeping us cool in the summer and warm all winter. This is a great team of professionals from start to finish.

Craig B.

Craig B.

Amazing level of courtesy and professionalism. Communication was great and the price was more than reasonable. Highly recommend.

Chip M.

Chip M.

Guys came and installed two full systems at the house. Respectful, cleaned up after themselves and answered any and all questions. Thank you again!! Definitely recommend!

Jason H.

Jason H.

Very knowledgeable and courteous. Toured me through all the functions of the new unit. Completed work very neatly and respectfully. Would recommend to anyone.

Derek S.

Derek S.